excellent reviews view over 8000 reviews
next day delivery over 500,000 items in stock
no hassle returns buy with confidence

240V Switch (5 Terminal) for Belle Minimix 130, 150 Mixers - OEM No. 70/0194

240V Switch (5 Terminal) for Belle Minimix 130, 150 Mixers - OEM No. 70/0194
240V Switch (5 Terminal) for Belle Minimix 130, 150 Mixers - OEM No. 70/0194 240V Switch (5 Terminal) for Belle Minimix 130, 150 Mixers - OEM No. 70/0194
Rating:
90%
Part No.
70/0194
In stock
Dispatched today if ordered before 4pm
Dispatched next working day

£20.40 £17.00
belle.png

Description

240v Switch (5 Terminal).
Genuine Belle Part.
OEM No. 70/0194.

Suitable for the Following Applications:

Minimix 150 (04/2002 - 04/2007), Minimix 130, Maxi 140, Minimix 140, BWE40, BWE60, MiniAlpha, Minimix 110, Minimix 80, Minimix 60

CAUTION: All electrical items should be fitted by a qualified electrician.

Here is a troubleshooting guide to help fix a Belle Minimix 150 cement mixer that won't start or runs with low power:

1. Check the Power Source:

  • Ensure that the mixer is connected to a power source that is working.
  • Check the fuse and the socket outlet to make sure it is delivering power with a piece of equipment that is known to be working.

2. Check the Switch:

  • If the power source is working correctly, check the switch.
  • Look for any loose connections or signs of damage.
  • If the switch is damaged, broken or won't 'stay in', replace it.

3. Check the Capacitor:

  • If the switch is not the problem, then check the capacitor.
  • Look for any visible signs of damage or a buzzing sound.
  • If you notice any visible signs of damage to the capacitor, replace it.

4. Check the Fan:

  • Check for damage to the motor fan.
  • If the fan is damaged or missing fins it can cause the motor to overheat.
  • If the fan is damaged, replace it.

5. Check the Motor:

  • If the capacitor is not the issue, then the motor may be the problem.
  • Check the motor for any visible signs of damage, including broken wires or burnt-out parts.
  • If the motor is damaged, replace it.

6. Check the Wiring for Earth Faults:

  • Another common issue that can prevent the mixer from starting is an earth fault.
  • Check all wiring for any signs of damage or fraying. Test the circuit with a multimeter for earth faults.
  • If you notice any damage, replace the wiring.

By following these steps, you should be able to fix a Belle Minimix 150 cement mixer that won't start. However, if the problem persists, it is best to seek professional help from a qualified electrician.

Product Specifications

More Information
L&S Part No. 70/0194
Part Type Genuine Part
Manufacturer Altrad/Belle
OEM No. 70/0194
Unit of Sale 1
Applications Minimix 150, Minimix 130, Maxi 140, Minimix 140, BWE40, BWE60, MiniAlpha, Minimix 110, Minimix 80, Minimix 60
Fits Brands Belle
Machine Type Mixers
Fits Models Minimix 150 |  Minimix 130 |  Maxi 140 |  Minimix 140 |  BWE40 |  BWE60 |  MiniAlpha |  Minimix 110 |  Minimix 80 |  Minimix 60

Reviews 2

Add a review
Write Your Own Review
You're reviewing:240V Switch (5 Terminal) for Belle Minimix 130, 150 Mixers - OEM No. 70/0194
Your Rating

Ask a Question (2)

Customer Questions
Mine is a Klinger born switch kb 01 kt t. Will this part fit this? It is 110v.
We have checked this for you and it should do the same job.
Is this switch a suitable replacement for a master mix junior MC110 cement mixer.
I can confirm that switch should be suitable.